Case Study

Case study: Pre-Heat and Main-Heat System

These were used to produce an artificial turf type material for sports grounds in the US.

There were 2 heating systems: Pre-heat and a Main heat system to be positioned over a conveyor system. Longer angle brackets were included per the customers specification.

Pre-Heat System

Oven frame Stainless Steel, Perforated aluminium back
Element Type SFEH 600W 480V × 16 (4 with embedded TC/k)
Control Zones 4
Total power 9.6kW
Oven Size Approx. external dimensions 610mm (24″) × 610mm (24″)
Element array 16 heaters- 4 × 4 heater array
Electrical connection 6100mm (20′) flexible metallic conduit with quick connect plug.

Main Heat System

Oven frame Stainless Steel, Perforated aluminium back
Element Type SFEH 600W 480V × 192 (4 with embedded TC/k)
Control Zones 4
Total power 115.2kW
Oven Size Approx. external dimensions 6096mm (240″) × 610mm (24″)
Element array 192 heaters- 4 × 48 heater array
Electrical connection 3000mm (10′) flexible metallic conduit with quick connect plug.

Components Used

We look forward to hearing from you